LIMESTONE CONTACTORS

 LIST OF CONTENTS

  Introduction

  Process Description

  Typical Contactor

  Design Criteria

  Photos, Plans & Specs

  Treatment Performance

  Operational Skills

  Automation Potential

  Advantages

  Limitations & Concerns

  Pilot Plant Objectives

  Costs 

  References

  Contacts & Facilities

 

PHOTOS, PLANS AND SPECIFICATIONS - CONTINUED

iv. Photos of Limestone Contactor in the Canary Islands, Spain

The following photos show examples of the limestone contactors designed by the Canary Islands Water Center. It is used to treat desalinated water from the reverse osmosis plants in the Canary Islands. The salinity and CO2 content of the desalinated water vary from one reverse osmosis plant to another but the typical characteristics are pH = 5.6 to 6, CO2 = 30-45 ppm and EC=600-1500 µS/cm (Hernández, 2003). The limestone contactors use 98% calcium carbonate with media size of 3 mm (Hernández, 2003). Due to variation in desalinated water quality from plant to plant, recommendations are to carry out pilot test to define accurate design parameters. The contactor may be easily added to an existing plant or custom-built for each installation and type of water (Centro Canario del Agua, 2003).

 

Page Number 26